FIRE & SAFETY


There is an automatic fire extinguishing system in the engine room. This CO2 system consists of a tank and manual releases, and plumbing and automatic releases in the engine room. Only the engine room is covered by this system. The manual releases are located in the lazarette on the bottle itself and in the guest quarters passage way, above and to the left of the forward engine room door. If the system is activated it will automatically shut down the main engine and the engine room fan. The shutdown switch is located on the overhead above the black water pump, engine room starboard aft corner. Press it in to reset or pull it out to test. AFTER ACTIVATING THE ENGINE ROOM EXTINGUISHING SYSTEM, CLOSE ALL THREE E.R. AIR INTAKES ON THE MAIN DECK. THE COVERS ARE LOCATED IN THE STERN STORAGE CABINET. There are fire extinguishers scattered throughout the boat. Here is a list: Engine room forward entrance on wall - halon Engine room under the vice - CO2 Engine room behind fuel transfer pump - halon 15' tender - CO2 Pantry area, port side - halon Salon, port/aft - halon Cockpit, locker - CO2 Master stateroom, behind entry door - halon Port cabin, wall behind door - halon Starboard cabin, wall behind door - halon Crew cabin, under desk on wall - halon Pilothouse, port wall - halon

 

 